Carbon Monoxide Detector EN50291 10 Years CO Sensor Portable Carbon Monoxide Alarm For Home RV Travel LCD Dispaly AA Batteries
121,31 lei – 329,70 leiInterval de prețuri: 121,31 lei până la 329,70 lei
Livrare
- Livrare prin curier
Livrarea se va face rapid in termenii si conditiile de livrare
10-12 zile
Gratuit
- Livrare rapida
Optional avem metoda de livrare rapida
7-10 zile
35 Ron
- Garantia producatorului
- 30 de zile retur
Reduceri Zilnice
Descriere
- High-concerned chemical: None
- Model Number: CA12
- Brand Name: CCEsafety
- Origin: Mainland China
- Type: Carbon Monoxide Detectors
- Concentration range displayed: 10-550PPM
- Power source: DC3V,2PCSAAbatteries
- Sensor Life: 10 years
- Battery service life: 3 years
- Certificate: CE EN50291-1:2018
- Static working current: <35uA
- Alarm current: <70mA
- Alarm sound: >85dB(3M distance)
- Dimension: 120X74X31mm
- Weight: 125g

Carbon monoxide, an invisible danger,CA12 Carbon MonoxideAlarm, 24-hour real-time monitoring, builds a safety line for you and your family!
Product Highlights:
★LCD display, clear and intuitive★
Real-time display of carbon monoxide concentration, so that you can see the safety status of your home at a glance.
★Low concentration alarm, preventive measures★
Sensitive CO sensor, even low concentration of carbon monoxide can alarm in time, giving you precious escape time.
★Sound and light alarm, timely reminder★
85dB Alarm, with eye-catching three-color indicator light (green: normal power, yellow: fault reminder, red: alarm indication), even in the middle of the night can promptly alert you to changes in carbon monoxide in the environment.
★Replaceable battery power supply★
Powered by AA batteries, the battery life is up to 3 years.When the power is exhausted, you only need to replace the battery without throwing away the entire carbon monoxide detector, which is green and saves life.
★Authoritative certification, quality assurance★
Passed EN50291 certification, reliable quality, stable performance, providing you with more professional protection.
It is recommended that you do not buy cheap carbon monoxide sensors because of the inaccurate detection of inexpensive carbon monoxide, Short life and high failure rates. Imagine how terrible it would be if a carbon monoxide leak occurred but the detector could not be alerted in time.
★High-end sensors★
Our carbon monoxide detector USES chips imported from the United States and NEMOTO high-precision detection sensors imported from Japan, with high detection accuracy and low false alarm rate. The CO Sensor Life Is 10 Years.
★Multiple application scenarios★
Depending on the source of carbon monoxide, you can install it near the fireplace, in the garage, living room, RV, kitchen, truck, and more.
Technical Parameters:
|
Power source |
2xAA battery |
|
Concentration range displayed |
10-550PPM |
|
Accuracy of Digital Display |
A) 30PPM ±10PPM |
|
Quiescent current: |
< 35uA |
|
Alarm current |
<70mA |
|
Working condition: temperature |
-10ºC~+45ºC |
|
Relative humidity |
0-93% |
|
Audible alarm |
>85dB (3 meters from the unit) |
|
Dimension |
120*74*31MM |
|
CO Sensor Life |
10 Years |
|
Weight |
125G |








Note: When installing, please open the back cover. Tear off the plastic cover of the battery, then install the battery and it can be used normally.
A.Power-up prompt (It indicates power-up.)

B.CO concentration (The LCD display shows CO concentration in PPM.)
When CO concentration is less than 10 PPM, it shows 0 PPM.
When CO concentration is more than 550 PPM, it shows “Hco”
When CO concentration is more than 550 PPM, it is very dangerous.


C.Testing operation (It indicates manual testing is in progress.)

D.Fault warning (It indicates fault warning.)

E.End-of-life warning(It indicates end of unit life, and the product needs to be replaced.)

F.Program code error warning(It indicates an error in the program code.)

Power-up prompt
When batteries are installed and the detector is powered up, power-up prompt will be given. It indicates that the power supply is normally connected, and the indicator lights and buzzer are working normally.
The LCD display shows ”EN”.
Normal operation
The detector will enter normal operation within 20 to 30 seconds after power-up. The Power indicator flashes every 45 seconds. When there is CO in the air, the Power indicator flashed every 30 seconds. The Fault indicator and Alarm indicator are off.
Alarm condition
The alarm won’t stop until CO concentration is lower than 40PPM. Put the detector in clean air, the alarm will terminate automatically in 6 minutes, or you can quit alarm condition by pressing and holding the TEST button for 1 to 3 seconds.
Alarm silence
When the detector is in alarm condition and the CO concentration is less than 200 PPM, press the TEST button and it will enter alarm silence condition. Alarm silence condition is the same as alarm condition except the buzzer doesn’t beep temporarily. The Alarm indicator still flashes. Alarm silence condition lasts less than 10 minutes. Press the TEST button in alarm silence condition, and it will recover alarm condition immediately.
Low CO concentration warning
When CO concentration is greater than 30PPM for a duration of more than 60 minutes, or when CO concentration is greater than 40PPM for a duration of more than 40 minutes, low CO concentration warning will be made.
Low CO concentration warning won’t stop until CO concentration is less than 25 PPM.
Testing
Press the TEST button, and the Power, Fault and Alarm indicators will flash once at the same time. If the detector is working properly, then one cycle of alarm will be made. If there is malfunction, then fault warning will be made.
When testing, the LCD display shows ”- – -”.
Steps of alarm installation
a) Take out the mounting plate and line it with the wall in the position that you have chosen for installation. Mark the holes with a pencil dot. With the aid of your wall punch and hammer, make two holes (6mm diameter, 40mm depth) on the marked spots.
b) Insert the two plastic anchors into the holes. Secure the mounting plate to the wall upwards by screwing.
c) After making sure the mounting plate is secured to the wall, power on the detector and test. If the test result is normal, then slide the alarm down over the mounting plate until it snaps into place.
Figure 1: Location of CO alarm in a room with a fuel burning appliance
Figure 2: CO alarm in a room with sloped ceilings
Note: The CO Alarm should be located at the high side of the room.
Figure 3: CO alarm in bedrooms and other rooms away from appliances (i.e. at breathing level)